Circuito DPED105BAS
Distribuidora EdeNorte - Provincia Santiago
| Mes-Año | Jul26 | Jun26 | May26 | Abr26 | Mar26 | Feb26 | Ene26 | Dic25 | Nov25 | Oct25 | Sep25 | Ago25 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Clasificación | D | D | D | D | D | D | D | D | D | D | D | D |
| Clientes | 842 | 842 | 836 | 841 | 825 | 800 | 788 | 790 | 790 | 789 | 789 | 792 |
| % Nivel Cobranza | 0.00% | 85.47% | 94.84% | 81.44% | 115.30% | 88.38% | 99.99% | 109.83% | 94.51% | 101.85% | 95.51% | 88.70% |
| % Nivel Pérdida | 0.00% | -14.58% | -52.23% | -29.44% | -19.60% | -48.84% | -33.11% | -26.09% | -28.23% | 26.69% | 20.41% | 35.49% |
| Energía Suministrada (GWh) | 0 | 0.13 | 0.09 | 0.1 | 0.09 | 0.08 | 0.09 | 0.1 | 0.1 | 0.19 | 0.19 | 0.22 |
| Energía Facturada (GWh) | 0 | 0.15 | 0.13 | 0.13 | 0.11 | 0.12 | 0.12 | 0.12 | 0.13 | 0.14 | 0.15 | 0.14 |
| Energía Cobrada (GWh) | 0 | 0.13 | 0.12 | 0.11 | 0.13 | 0.11 | 0.12 | 0.14 | 0.12 | 0.14 | 0.15 | 0.12 |
| % Servicio | 94.52% | 97.24% | 97.55% | 99.17% | 98.29% | 95.58% | 96.62% | 99.88% | 95.74% | 96.42% | 95.26% | 96.59% |
| % Sin Servicio | 5.48% | 2.76% | 2.45% | 0.83% | 1.71% | 4.42% | 3.38% | 0.12% | 4.26% | 3.58% | 4.74% | 3.41% |
| Interrupción Programada (Hrs) | 25.00 | 5.00 | 12.00 | 4.00 | 1.00 | 7.00 | 10.00 | 9.00 | 19.00 | 5.00 | 6.00 | 0.00 |
| Interrupción Ejecutada (Hrs) | 39.46 | 19.87 | 17.67 | 6.00 | 12.28 | 31.83 | 24.31 | 0.87 | 31.09 | 26.12 | 34.58 | 24.88 |
| Promedio Interrupción Diarias (Hrs) | 1.30 | 0.65 | 0.58 | 0.20 | 0.40 | 1.05 | 0.80 | 0.03 | 1.02 | 0.86 | 1.14 | 0.82 |
| Fecha | Tipo Interrupción | Hora Apertura | Hora Cierre | Duración Total | Causa |
|---|---|---|---|---|---|
| 18/08/2026 | Programada | 13:00:00 | 18:00:00 | 5 | |
| 13/08/2026 | Ejecutada | 19:26:44 | 19:32:52 | 2.06 | DISPARO DESCONOCIDO // FALLAS ETED, SOBRECARGA DE LINEA TRANSMISION // LÍNEAS LIGADAS REDES |
| 13/08/2026 | Ejecutada | 17:08:03 | 17:11:48 | 2.06 | DISPARO DESCONOCIDO // FALLAS ETED, SOBRECARGA DE LINEA TRANSMISION // LÍNEAS LIGADAS REDES |
| 13/08/2026 | Ejecutada | 15:18:05 | 17:06:39 | 2.06 | DISPARO DESCONOCIDO // FALLAS ETED, SOBRECARGA DE LINEA TRANSMISION // LÍNEAS LIGADAS REDES |
| 13/08/2026 | Ejecutada | 12:00:37 | 12:05:49 | 2.06 | DISPARO DESCONOCIDO // FALLAS ETED, SOBRECARGA DE LINEA TRANSMISION // LÍNEAS LIGADAS REDES |
| 12/08/2026 | Ejecutada | 10:44:01 | 10:47:34 | 3.69 | CORRECTIVO EN CONDUCTOR DE FASE // INTERCONEXION DE PROYECTOS // PERDIDA DE TENSION DE LA 12.5 |
| 12/08/2026 | Ejecutada | 10:39:14 | 10:42:29 | 3.69 | CORRECTIVO EN CONDUCTOR DE FASE // INTERCONEXION DE PROYECTOS // PERDIDA DE TENSION DE LA 12.5 |
| 12/08/2026 | Ejecutada | 08:53:01 | 09:09:19 | 3.69 | CORRECTIVO EN CONDUCTOR DE FASE // INTERCONEXION DE PROYECTOS // PERDIDA DE TENSION DE LA 12.5 |
| 12/08/2026 | Ejecutada | 05:41:27 | 08:52:58 | 3.69 | CORRECTIVO EN CONDUCTOR DE FASE // INTERCONEXION DE PROYECTOS // PERDIDA DE TENSION DE LA 12.5 |
| 12/08/2026 | Ejecutada | 05:32:30 | 05:39:19 | 3.69 | CORRECTIVO EN CONDUCTOR DE FASE // INTERCONEXION DE PROYECTOS // PERDIDA DE TENSION DE LA 12.5 |