Circuito CAPO09
Distribuidora EdeEste - Provincia Distrito Nacional
| Mes-Año | Oct26 | Sep26 | Ago26 | Jul26 | Jun26 | May26 | Abr26 | Mar26 | Feb26 | Ene26 | Dic25 | Nov25 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Clientes | 4323 | 4323 | 4297 | 4267 | 4267 | 4656 | 4248 | 4447 | 3670 | 4573 | 4472 | 4243 |
| % Nivel Cobranza | 0.00% | 65.54% | 62.28% | 65.86% | 67.27% | 61.76% | 65.26% | 64.64% | 66.68% | 66.74% | 71.09% | 68.27% |
| % Nivel Pérdida | 0.00% | 87.19% | 87.72% | 88.67% | 87.98% | 85.74% | 84.50% | 82.25% | 82.82% | 81.32% | 83.25% | 83.63% |
| Energía Suministrada (GWh) | 0 | 6.91 | 7.64 | 7.58 | 7.19 | 6.5 | 5.63 | 5.08 | 4.63 | 5.27 | 5.65 | 5.85 |
| Energía Facturada (GWh) | 0 | 0.89 | 0.94 | 0.86 | 0.86 | 0.93 | 0.87 | 0.90 | 0.80 | 0.98 | 0.95 | 0.96 |
| Energía Cobrada (GWh) | 0 | 0.58 | 0.58 | 0.56 | 0.58 | 0.57 | 0.57 | 0.58 | 0.53 | 0.66 | 0.67 | 0.65 |
| % Servicio | 96.42% | 96.16% | 97.27% | 97.76% | 98.06% | 91.73% | 96.27% | 98.62% | 97.02% | 99.42% | 99.46% | 97.12% |
| % Sin Servicio | 3.58% | 3.84% | 2.73% | 2.24% | 1.94% | 8.27% | 3.73% | 1.38% | 2.98% | 0.58% | 0.54% | 2.88% |
| Interrupción Programada (Hrs) | 70.00 | 68.00 | 8.00 | 12.00 | 0.00 | 42.00 | 36.00 | 72.00 | 36.00 | 19.00 | 15.00 | 0.00 |
| Interrupción Ejecutada (Hrs) | 25.78 | 27.65 | 19.68 | 16.10 | 13.98 | 59.53 | 26.85 | 9.95 | 21.48 | 4.20 | 3.98 | 21.00 |
| Promedio Interrupción Diarias (Hrs) | 0.85 | 0.91 | 0.65 | 0.53 | 0.46 | 1.96 | 0.88 | 0.33 | 0.71 | 0.14 | 0.13 | 0.69 |
| Fecha | Tipo Interrupción | Hora Apertura | Hora Cierre | Duración Total | Causa |
|---|---|---|---|---|---|
| 11/11/2026 | Programada | 08:20:00 | 16:20:00 | 8.00 | DISTRIBUCION (FACILIDADES OPERATIVAS) - PARA FACILITAR TRABAJOS A OTRO CTO // SS/EE (MATTO. PREV.) - PRUEBA Y MATTO TRANSFORMADOR POTENCIA // DISTRIBUCION (DISPARO/AVERIAS) - RECORRIDO DE LINEA (NO FALLAS) |
| 11/11/2026 | Ejecutada | 17:40:00 | 17:45:00 | 8.30 | DISTRIBUCION (FACILIDADES OPERATIVAS) - PARA FACILITAR TRABAJOS A OTRO CTO // SS/EE (MATTO. PREV.) - PRUEBA Y MATTO TRANSFORMADOR POTENCIA // DISTRIBUCION (DISPARO/AVERIAS) - RECORRIDO DE LINEA (NO FALLAS) |
| 11/11/2026 | Ejecutada | 08:53:00 | 16:59:00 | 8.30 | DISTRIBUCION (FACILIDADES OPERATIVAS) - PARA FACILITAR TRABAJOS A OTRO CTO // SS/EE (MATTO. PREV.) - PRUEBA Y MATTO TRANSFORMADOR POTENCIA // DISTRIBUCION (DISPARO/AVERIAS) - RECORRIDO DE LINEA (NO FALLAS) |
| 11/11/2026 | Ejecutada | 04:46:00 | 04:53:00 | 8.30 | DISTRIBUCION (FACILIDADES OPERATIVAS) - PARA FACILITAR TRABAJOS A OTRO CTO // SS/EE (MATTO. PREV.) - PRUEBA Y MATTO TRANSFORMADOR POTENCIA // DISTRIBUCION (DISPARO/AVERIAS) - RECORRIDO DE LINEA (NO FALLAS) |
| 05/11/2026 | Ejecutada | 10:08:00 | 10:12:00 | 0.07 | DISTRIBUCION (DISPARO/AVERIAS) - JUMPER MT ABIERTO |
| 04/11/2026 | Programada | 09:20:00 | 15:20:00 | 6.00 | DISTRIBUCION (PROYECTOS) - CONSTRUCCION DE LINEA MT // DISTRIBUCION (DISPARO/AVERIAS) - JUMPER MT ABIERTO |
| 04/11/2026 | Ejecutada | 19:37:00 | 19:41:00 | 0.30 | DISTRIBUCION (PROYECTOS) - CONSTRUCCION DE LINEA MT // DISTRIBUCION (DISPARO/AVERIAS) - JUMPER MT ABIERTO |
| 04/11/2026 | Ejecutada | 09:47:00 | 10:01:00 | 0.30 | DISTRIBUCION (PROYECTOS) - CONSTRUCCION DE LINEA MT // DISTRIBUCION (DISPARO/AVERIAS) - JUMPER MT ABIERTO |